Joseph Ferano 2250548b07 A test that sees a process die on a signal names the signal, not OCaml's number for it
OCaml numbers the signals negatively and in its own order: SIGTERM is -11. The globals daemon's "transient signal 11" was a SIGTERM, not a segfault.